Description
Model |
E70096: EV-1 |
|
|
Nominal supply voltage |
12 V (powered by SeaTalkng system) |
Operating voltage range |
10.8 V to 15.6 V dc |
Power consumption
(taken from SeaTalkng system) |
30 mA |
SeaTalkng LEN
(Load Equivalency Number) |
1 |
Sensors |
3-axis digital accelerometer 3-axis digital compass 3-axis gyro digital angular rate sensor |
Data connections |
SeaTalkng
NMEA 2000 DeviceNet (EV-2 only) |
Installation environmental |
Operating temperature: -20°C to +55°C (-4°F to +131°F) Storage temperature: -30°C to +70°C (-22°F to +158°F) Relative humidity: max 93% Waterprrof rating: IPX 6 |
Dimensions |
Diameter: 140 mm (5.5 in) Depth (including mounting enclosure): 35 mm (1.4 in) Depth (including wall bracket): 95 mm (3.8 in) |
Weight |
0.29 kg (0.64 lbs) |
EMC compliance |
Europe: 2004/108/EC Australia and New Zealand |